The Xentra 22KW VFD Solar Pumping Inverter delivers high-performance variable frequency drive technology optimized for solar-powered water pumping applications. With 22 kilowatt capacity, this inverter efficiently converts DC solar energy into AC power while regulating motor speed to match water demand, reducing energy waste and extending system lifespan. Built-in MPPT technology maximizes solar panel output across varying light conditions. Ideal for agricultural irrigation, livestock watering, and remote water supply systems, this inverter combines reliability with intelligent power management for sustainable water solutions.
|
Xentra VFD |
|
|
Model |
5.5K-22K |
|
INPUT |
|
|
Input Voltage |
AC, 3 PH, 380V(-15%) - 480V(+10%) |
|
Rated Frequency |
50/60 Hz |
|
Frequency Range |
± 5% (47.5 - 63Hz) |
|
OUPUT |
|
|
Output Voltage |
O-Input Voltage |
|
Maximum Output Frequency |
0.1-500HZ |
|
Output Power |
Please refer to Rated Parameter table |
|
Output Current |
Please refer to Rated Parameter table |
|
BASIC PARAMETERS |
|
|
Highest frequency |
Vector control: 0-320Hz |
|
Vector control:0-500Hz
|
|
|
Carrier frequency |
0.8KHz-16KHz |
|
Adjusted automatically according to the load characteristics |
|
|
Input frequency resolution |
Digital setting: 0.01Hz |
|
Analog setting: Highest frequency*0.025% |
|
|
Control mode |
Close-loop vector control (FVC) Open-loop vector control (SVC), V/F control |
|
Starting torque |
0.5Hz / 150% (SVC);0Hz/180% (FVC) |
|
Adjustable speed ratio |
1:100 (SVC); 1:1000 (FVC) |
|
Speed control accuracy |
± 0.5% (SVC); ±0.02% (FVC) |
|
Overload capablity |
150% of rated current: 60 seconds 220% of rated curent: 1 second |
|
Torque boost |
Auto torque boost; Range of manual torque boost 0.1%-30.0% |
|
V/F curve |
Three types: Linear, Multi-point, square curve |
|
(12 power, 14 power, 16 power, 1.8 power, 2 power) |
|
|
V/F separation
|
Full separation, Half separation |
|
Acceleration and deceleration time |
Linear and S-curve acceleration and deceleration modes available. Four kinds of acceleration and deceleration time, The range of acceleration and deceleration time is 0.0-6500.0s |
|
DISPLAY BUTTONS |
|
|
Keypad |
0.75K-3.7K model: standard keypad (Optional detachable keypad can be purchased seperately) |
|
5.5K-22K model: standard detachable keypad |
|
|
Copy parameters (Only for 55-22K model) |
Parameters can be copied through the standard external keyboard |
|
LED display |
Display parameters |
|
Key lock and function selections |
It allows users to partialy or fully lock the keys or define operated range for partial keys to prevent misoperation |
|
Protective function |
Motor short-circuit detection at power-on, output phase loss protection, over-curent protection, over-voltage protection, under-voltage protection, overheat protection, overload protection and etc. |
|
ENVIRONMENT |
|
|
Storage temperature |
-20°C-60°C |
|
Operation temperature
|
-10°C-50°C (If temperarture is higher than 40°C, the output capacity will be derated 1% per 1°C increase) |
|
Storage humidity |
<90%RH |
|
Operation humidity |
<90%RH |
|
Noise Level |
50dBA max. |
|
STANDARD |
|
|
EMC |
Standards : IEC 61800-3,C3 |
|
Safety |
Standards : IEC 61800-5-1 |
|
INTERACE |
|
|
Communication Port |
RS-485 |